  • TRACKER 280 SERIES Digital Panel Indicator for Frequency, Timing, Counting, Batching, Rate, Measurement and Display

TRACKER 280 SERIES Digital Panel Indicator for Frequency, Timing, Counting, Batching, Rate, Measurement and Display

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
0

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail TRACKER 280 SERIES Digital Panel Indicator For Frequency, Timing, Counting, Batching, Rate, Measurement And Display

Batch Counter Control Functions The Batch Controller functions are used for controlling batching type applications. The user can select from the following control modes: Mode 1 On trigger, output 1 & 2 are turned OFF - unit counts ( in engineering units) from a pre-set ‘ reset’ value. When batch setpoint 1 is reached, output 1 is turned ON - counts continue to be accumulated. When batch setpoint 2 is reached, output 2 is turned ON - counts continue to be accumulated. Unit waits for the next trigger, which must be toggled OFF then ON to reset the batch control. Mode 2 On trigger, output 1 & 2 are turned OFF - unit counts ( in engineering units) from a pre-set ‘ reset’ value. When batch setpoint 1 is reached, output 1 is turned ON - counts continue to be accumulated. When batch setpoint 2 is reached, O/ P 2 is turned ON and O/ P 1 OFF - counts continue to be accumulated. Unit waits for the next trigger, which must be toggled OFF then ON to reset the batch control. Mode 3 On trigger, output 1 & 2 are turned OFF - unit counts ( in engineering units) from a pre-set ‘ reset’ value. When batch setpoint 1 is reached, output 1 is turned ON - counts continue to be accumulated. When batch setpoint 2 is reached, output 2 is turned ON - counts continue to be accumulated. Automatic re-trigger will occur if the trigger state is correct ( no need to toggle trigger) . Counts continue to be accumulated. Mode 4 On trigger, output 1 & 2 are turned OFF - unit counts ( in engineering units) from a pre-set ‘ reset’ value. When batch setpoint 1 is reached, output 1 is turned ON - counts continue to be accumulated. When batch setpoint 2 is reached, O/ P 2 is turned ON and O/ P 1 OFF - counts continue to be accumulated. Automatic re-trigger will occur if the trigger state is correct ( no need to toggle trigger) . Counts continue to be accumulated. Jakarta - Indonesia Phone : 021-29563045 ( hunting) Hp : 08156141954 Pin BB : 284152F7
Tampilkan Lebih Banyak